Equinox Systems Cirrus Manuale Pagina 66

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 147
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 65
66 ©Copyright 2006 Cirrus Logic, Inc. DS651PM25
CobraNet Programmer’s Reference
Management Interface Variable Reference
Name
firmwareBootVersion
Description
Configuration record revision number. The configuration record contains the MAC address for the
interface and other permanent initialization parameters.
Host Address
0x3
SNMP Object ID
1.3.6.1.4.1.2680.1.1.1.4
Type
Integer
Attributes
Read-only
Implemented Version
2.1.0
Name
firmwareMfgId
Description
Identifies the manufacturer of the CobraNet device. 0 represents unknown.
Host Address
0x4
SNMP Object ID
1.3.6.1.4.1.2680.1.1.1.5
Type
Integer
Attributes
Read-only
Implemented Version
2.1.0
Name
firmwareMfgProductId
Description
Identifies product type per manufacturer. Product identifiers are unique per manufacturer identifier. 0
represents unknown product.
Host Address
0x5
SNMP Object ID
1.3.6.1.4.1.2680.1.1.1.6
Type
Integer
Attributes
Read-only
Implemented Version
2.1.0
Vedere la pagina 65